UL 3700 Explained: The Plug-In Solar Safety Standard

UL 3700 is the first US safety standard written specifically for plug-in (balcony) solar systems. It was published in December 2025, and UL's certification programme for it launched in January 2026. It exists because plug-in solar did not fit the older categories: a system designed to feed power into an ordinary wall outlet, installed by the user with no electrician and no interconnection study, needed its own safety rules.

What each state's law requires

Ten states have enacted plug-in solar laws, and they do not all ask for the same thing. Some name UL 3700 directly; Connecticut's law instead names UL 1741, the inverter standard; several others require listing by a nationally recognized testing laboratory (NRTL) without naming a standard at all. The table below is generated from the same records as our state pages (last checked November 23, 2026), so it updates whenever a record does:

StateLawCertification requirement in the statute
Utah
Law in effect
HB 340UL or equivalent certification required
California
Law passed — not yet in effect
SB 868 (Chapter 985, Statutes of 2026)Must be certified as a plug-in photovoltaic system by Underwriters Laboratories or an equivalent nationally recognized testing laboratory (whole-system certification, i.e. to UL 3700), and meet the standards of the most recent National Electrical Code and the California Electrical Code
New Jersey
Law passed — not yet in effect
Garden State Balcony Solar Act (S2368/A4836, P.L.2026, c.82)Must be listed or certified to UL 3700 or a comparable standard (or combination of standards) by a nationally recognized testing laboratory; a device with output of 400 W or less at the outlet is exempt from listing, electrical code or construction code provisions that would require alterations to the building's wiring or panel
Maine
Law in effect
LD 1730 (P.L. 2025, c. 644)Must be listed or certified in accordance with UL 3700 or a comparable standard by a nationally recognized testing laboratory, or configured in accordance with the National Electrical Code
Vermont
Law in effect
Act 149 (S.202)Must comply with UL 3700 for plug-in photovoltaic systems by UL Solutions or an equivalent certification by an equivalent nationally recognized testing laboratory, and be installed and operated in compliance with IEEE 1547-2018
Colorado
Law in effect
HB26-1007 (Chapter 127)Must be labeled and listed by a nationally recognized testing laboratory; a device of 391 W or less is exempt from listing provisions that would require alterations to building wiring
Maryland
Law in effect
HB 1532 (Chapter 353) — Public Utilities § 7-321Must be listed by Underwriters Laboratories or an equivalent nationally recognized testing laboratory; a system with a maximum power output to a standard electrical outlet of not more than 391 W is exempt from listing provisions that would require alterations to the building's premises, wiring, or electrical panels
Connecticut
Law in effect
Public Act 26-127 (HB 5340), Sec. 9Must be certified by Underwriters Laboratories or an equivalent nationally recognized testing laboratory and meet UL 1741 (Connecticut names the UL 1741 inverter standard, not UL 3700), the National Electrical Code, IEEE 1547, and the State Building Code
New Hampshire
Law passed — not yet in effect
SB 540 (Chapter 262, Laws of 2026)Must be certified by a nationally recognized testing laboratory to nationally recognized safety standards and comply with national standards for interconnection and interoperability of distributed energy resources; the statute does not name UL 3700 or UL 1741
Virginia
Law passed — not yet in effect
HB 395 / SB 250 (2026 Acts ch. 1052 and 998)Must be certified by a nationally recognized testing laboratory (as described in 29 C.F.R. § 1910.7) or an equivalent laboratory and meet the standards of the most recent National Electrical Code; the statute does not name UL 3700 — a Commerce and Trade work group was directed to report on safety standards by November 15, 2026. A device with output of 391 W or less is exempt from listing provisions that would require changes to the premises, wiring or panels

Texas is not in the table: it has no plug-in solar law, so there is no state certification requirement to list. See the Texas page for what that means and what the legal alternative is.

System certification vs component certification

This distinction decides most "is it certified?" arguments in plug-in solar today:

Where certification stands today

As of sources published April–October 2026, no complete kit had finished UL 3700 system certification. The first reported progress was at component level: component-level certifications for Hoymiles and APsystems microinverters were reported in July 2026. That gap — laws in force, certified products not yet on sale — is why several states' requirements cannot currently be met with an off-the-shelf kit, and why our tracker records each product's status with dated sources instead of repeating vendor claims.

How to verify a listing in UL Product iQ

UL Product iQ is UL's public directory of certified products. To check a claim yourself:

  1. Open UL Product iQ (UL's free certification directory) and search for the manufacturer's name, or the exact product or model name.
  2. Open the product's certification record and check which standard it was certified to. For a plug-in solar system, you are looking for UL 3700; a record under a different standard (for example UL 1741, the inverter standard) is a component listing, not system certification.
  3. Check what the record covers: the complete kit as sold, or only a component inside it — and confirm the model numbers match the product being sold.
  4. Cross-check the company name on the record against the seller, and look for the corresponding UL Mark on the product itself.
  5. If there is no record, treat the product as not certified — whatever the product page says. That is the rule our methodology applies too.

General information, not legal advice. Certification statuses change; the tracker and state pages carry the date each record was last verified.